630167_5_Manual_Installation_US_R-emotion ST900 Direct Vent Gas Fireplace Installation Manual NORTH AMERICA EDITION Manu
630167_5_Manual_Installation_US_R-emotion 11.0 Removing the Firebox Glass: Pull the four hooks shown below towards you and then away from the gl
630167_5_Manual_Installation_US_R-emotion 12.0 Installing the Flue System: Ensure all flue components are Simpson Duravent Direct Vent Pro 5” x 8,
630167_5_Manual_Installation_US_R-emotion 12.5 Vertical Only Flue Diagram: Use this diagram to
630167_5_Manual_Installation_US_R-emotion 12.6 Horizontally Terminating Flue Diagram: Use this
630167_5_Manual_Installation_US_R-emotion 12.7 Vertically Terminating flue with a Horizontal Offset:
630167_5_Manual_Installation_US_R-emotion 12.8 Standard Flueing Configurations: The following flue components are available from your escea distri
630167_5_Manual_Installation_US_R-emotion 12.9 Locating the Flue Terminal: The flue terminal must be located using the information given in the fol
630167_5_Manual_Installation_US_R-emotion 12.10 Supporting the flue system: Wall straps are required to fix the flue system in place for each ins
630167_5_Manual_Installation_US_R-emotion 13.0 Fitting the Flue Restrictor: If your flueing configuration requires that you fit a flue restrictor
630167_5_Manual_Installation_US_R-emotion 14.0 Converting to Propane Gas: Where a conversion to propane gas is needed, the following steps should
630167_5_Manual_Installation_US_R-emotion Important: The appliance shall be installed in accordance with; • This installation instruction bookle
630167_5_Manual_Installation_US_R-emotion Now, put the gas data (Propane sticker shown) sticker supplied in the conversion kit in onto the dataplate
630167_5_Manual_Installation_US_R-emotion 15.0 Placing the Fuel Bed Media: Your ST900 Gas fireplace will be supplied with a Fuel Bed kit. Follow
630167_5_Manual_Installation_US_R-emotion 16.0 Re-fitting the Glass Assembly To re-fit the glass assembly, place the bottom of the glass assembly
630167_5_Manual_Installation_US_R-emotion 17.0 Checking Operating Pressure: WARNING: The regulator that is supplied with the fireplace MUST NOT
630167_5_Manual_Installation_US_R-emotion 19.0 Commissioning the Fire: After the cladding and finishing processes are completed, the gasfitter mus
630167_5_Manual_Installation_US_R-emotion 3. The ST900 fascia uses these four hooks for attaching to the fire. Do this by lining up the fascia hoo
630167_5_Manual_Installation_US_R-emotion 2. Install the Heat Deflector to the top of the fireplace using the 3x supplied screws with the Heat
630167_5_Manual_Installation_US_R-emotion 19.3 Cleaning the ST900 Fascia: The fascia must be cold before starting any form of maintenance or clea
630167_5_Manual_Installation_US_R-emotion 20.0 Operating Instructions:
630167_5_Manual_Installation_US_R-emotion Note: If this is the first time running the ST900 the air will need to be purged from the gas lines. To do
630167_5_Manual_Installation_US_R-emotion Note: THERE ARE A FEW THINGS TO CONSIDER BEFORE INSTALLATION • Cavity Dimensions and Clearances •
630167_5_Manual_Installation_US_R-emotion 20.2 Switching off the ST900: To turn off the fire, push the OFF button, to shut down the gas flow to th
630167_5_Manual_Installation_US_R-emotion > Program mode: By default the program mode is not enabled. To enable program mode, enter configuratio
630167_5_Manual_Installation_US_R-emotion 20.4 Changing the display from Celsius to Fahrenheit: Go into Menu → Adjust menu → Unit. Press middle bu
630167_5_Manual_Installation_US_R-emotion 20.8 Pairing the Remote to the Control Unit: Install batteries to the battery pack and after a while the
630167_5_Manual_Installation_US_R-emotion 20.9 Initial configuration: To enter the configuration menu, press the OFF button on the remote control
630167_5_Manual_Installation_US_R-emotion 21.0 Sounds and Smells: Note: Each time the fireplace is lit from cold the glass will fog up with con
630167_5_Manual_Installation_US_R-emotion 22.0 Annual Service Check: The ST900 Fireplace should be serviced annually to ensure it continues to op
630167_5_Manual_Installation_US_R-emotion 24.0 Appendix A: Points to note when planning the Installation of the Escea DV flue: - This flue system
630167_5_Manual_Installation_US_R-emotion 24.1 Appendix B: 24.2 Appendix C: Clearances to Combustible Surfaces:
630167_5_Manual_Installation_US_R-emotion 24.3 Appendix D: Replacement Parts: Replacement parts for the ST900 gas fireplace are available from all
630167_5_Manual_Installation_US_R-emotion Contents: 1.0 Product Description 2.0 Creating the Cavity 3.0
630167_5_Manual_Installation_US_R-emotion 25.0 WARRANTY TERMS & CONDITIONS: LIMITED WARRANTY: Provided that the Product is installed as per ESC
630167_5_Manual_Installation_US_R-emotion 6. ESCEA is not responsible for damage arising from failure to follow instructions for the product's
630167_5_Manual_Installation_US_R-emotion
630167_3_Manual_Service_ST900_US_R‐emotion
630167_3_Manual_Service_ST900_US_R‐emotion
630167_3_Manual_Service_ST900_US_R‐emotion15.0 Troubleshooting Usethefollowingtroubleshootingcharttodiagnoseandfault‐findoperationaliss
630167_3_Manual_Service_ST900_US_R‐emotion12.0 Re‐assemble Oncetheserviceworkiscomplete,thefireshouldbere‐asse mbledbyreversingth
630167_3_Manual_Service_ST900_US_R‐emotion7.0 CleanPilotandMainBurnerJets: Withtheburnerremovedtheburnerjetisnowaccessible.Remov
630167_3_Manual_Service_ST900_US_R‐emotion5.0 RemoveControlTray[ifrequired]: Ifthethermocoupleneedstobereplaced,ortheControlTray
630167_3_Manual_Service_ST900_US_R‐emotion4.0 RemoveFireboxContents: Ensurethefireboxcontentshavecooleddowncompletely beforeattemp
630167_5_Manual_Installation_US_R-emotion 1.0 Product Description: The Escea ST900 decorative gas fireplace is designed to be built in
630167_3_Manual_Service_ST900_US_R‐emotion1.0 IsolatePowerandGasSupply:BeforeanyserviceandmaintenanceworkisdoneontheST900,thegas
630167_3_Manual_Service_ST900_US_R‐emotionContents: DIS‐ASSEMBLY‐ Isolatepowerandgassupply ‐ 1.0‐Removefascia‐2.0‐Remo
630167_3_Manual_Service_ST900_US_R‐emotion ST900 Direct Vent Gas Fireplace Service Guide NORTH AMERICA EDITION Important • It is re
630167_5_Manual_Installation_US_R-emotion 2.0 Creating the Cavity: The dimensioned drawing below shows the size of opening that must be created t
630167_5_Manual_Installation_US_R-emotion 2”2”2”20”4”4”2”2”2”2”MantleMantleRecessed TVFlush TV with small mantleMantle above fire Protruding fire20”
630167_5_Manual_Installation_US_R-emotion 5.2 Non-Combustible Mantle Clearances: If the entire installation (mantle, wall and cavity) is construct
630167_5_Manual_Installation_US_R-emotion 8.0 Connecting the Gas Pipe: An accessible inline isolation or service valve must be fitted and pipe ru